DIGI-44B Installation and Operation Guide Rev 140813 8001 Terrace Ave Phone: 608-831-0880 Suite 201 Toll-Free: 866-462-8649 Middlet
DIGI-44B Installation Guide Front Panel and IR Remote Operation Basic Routing To set a single route using the front panel of the DIGI-44B:
DIGI-44B Installation Guide IR Remote Operation The IR remote includes buttons for Next Input, Previous Input, and selection of a specific
DIGI-44B Installation Guide IP Address Assignment The DIGI-44B ships from the factory with a default IP address of 192.168.0.178. You can
DIGI-44B Installation Guide 6. Turn the power to the DIGI-44B on – after 5 seconds, the DIGI-44B will send some lines of information you can
DIGI-44B Installation Guide 14
DIGI-44B Installation Guide 4. Confirm the Docklight communication settings (Docklight -> Tools -> Project Settings) match the device.
DIGI-44B Installation Guide Static IP assignment via TCP/IP The Static IP address can be changed using TCP/IP 1. Download Docklight and th
DIGI-44B Installation Guide 5. Select “Use the following IP address”, and then enter the IP address you would like your computer to become.
DIGI-44B Installation Guide 10. In the “Send Sequences” window, press the Set IP (Use Wildcards) button. 11. Type the desired IP addres
DIGI-44B Installation Guide Web Control Logging into the DIGI-44B via Web Browser. The DIGI-44B routing can be controlled through a standar
DIGI-44B Installation Guide Important Safety Instructions Please completely read and verify you understand all instructions in this manu
DIGI-44B Installation Guide Changing the Password to the Web Control 1. Log into the Web Control utility by using the instructions above.
DIGI-44B Installation Guide RS232 and TCP/IP Commands RS232 Connection The RS232 control port requires a standard straight-through serial
DIGI-44B Installation Guide Output 3 Commands Function Command Response Select Input 1 cir 5E<CR><LF> s30<CR><LF> Th
DIGI-44B Installation Guide Misc. Commands Function Command Response Set IP Mode - DHCP dhc <CR><LF> “DHCP<CR><LF>”
DIGI-44B Installation Guide Troubleshooting Matrix does not power on Verify power outlet is active. Verify continuity in power cable.
DIGI-44B Installation Guide Technical Specifications DIGI-44B I/O Connections HDMI Inputs Four (4) HDMI Type A Receptacle (1 per input) HDM
DIGI-44B Installation Guide DIGIB-EMT Signal Characteristics Wide-Band Infrared (IR) 30 KHz to 56 KHz at 5V DC reference Physical Characte
DIGI-44B Installation Guide This page intentionally left blank. 27
DIGI-44B Installation Guide Thank you for your purchase. Please contact us with your questions and comments. Intelix 8001 Terrac
DIGI-44B Installation Guide Table of Contents Important Safety Instructions ...
DIGI-44B Installation Guide TCP/IP Connection ...
DIGI-44B Installation Guide Overview The Intelix DIGI-44B is a four input by four output HDBaseT HDMI matrix switcher. The Intelix DIGI-44
DIGI-44B Installation Guide Front Panel 1 - IR Receiver – For use with the included IR remote. 2 - Input Buttons –Buttons label
DIGI-44B Installation Guide Rear Panel 1 - Emitter Ports – IR emitters to control HDMI sources in the rack. 2 - IR Receiver Ports
DIGI-44B Installation Guide Installation Instructions Shelf Mounting Instructions The DIGI-44B comes with pre-installed feet and can be
DIGI-44B Installation Guide EDID Management HDMI signals require communication between the Source and Display equipment. The Display provid
Comments to this Manuals